Multicentre observational study of the Gatekeeper™ for faecal incontinence

Background A variety of therapeutic approaches are available for faecal incontinence. Implantation of Gatekeeper™ prostheses is a new promising option. The primary endpoint of this prospective observational multicentre study was to assess the clinical efficacy of Gatekeeper™ implantation in patients...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:British journal of surgery 2016-02, Vol.103 (3), p.290-299
Hauptverfasser: Ratto, C., Buntzen, S., Aigner, F., Altomare, D. F., Heydari, A., Donisi, L., Lundby, L., Parello, A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background A variety of therapeutic approaches are available for faecal incontinence. Implantation of Gatekeeper™ prostheses is a new promising option. The primary endpoint of this prospective observational multicentre study was to assess the clinical efficacy of Gatekeeper™ implantation in patients with faecal incontinence. Secondary endpoints included the assessment of patients' quality of life, and the feasibility and safety of implantation. Methods Patients with faecal incontinence, with either intact sphincters or internal anal sphincter lesions extending for less than 60° of the anal circumference, were selected. Intersphincteric implantation of six prostheses was performed. At baseline, and 1, 3 and 12 months after implantation, the number of faecal incontinence episodes, Cleveland Clinic Faecal Incontinence, Vaizey and American Medical Systems, Faecal Incontinence Quality of Life Scale and Short Form 36 Health Survey scores were recorded. Endoanal ultrasonography was performed at baseline and follow‐up. Results Fifty‐four patients were implanted. After Gatekeeper™ implantation, incontinence to gas, liquid and solid stool improved significantly, soiling was reduced, and ability to defer defaecation enhanced. All faecal incontinence severity scores were significantly reduced, and patients' quality of life improved. At 12 months, 30 patients (56 per cent) showed at least 75 per cent improvement in all faecal incontinence parameters, and seven (13 per cent) became fully continent. In three patients a single prosthesis was extruded during surgery, but was replaced immediately. After implantation, prosthesis dislodgement occurred in three patients; no replacement was required. Conclusion Anal implantation of the Gatekeeper™ in patients with faecal incontinence was effective and safe. Clinical benefits were sustained at 1‐year follow‐up. GatekeeperTM effective
ISSN:0007-1323
1365-2168
DOI:10.1002/bjs.10050