Antimony in blood and urine of infants

AIM: To establish a reference range for antimony in the serum and urine of infants in the first year of life. METHODS: 100 infants were selected randomly from the population. Each infant had a single blood and urine sample taken. Antimony was assayed using inductively coupled plasma mass spectrometr...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of clinical pathology 1998-03, Vol.51 (3), p.238-240
Hauptverfasser: Cullen, A, Kiberd, B, Matthews, T, Mayne, P, Delves, H T, O'Regan, M
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:AIM: To establish a reference range for antimony in the serum and urine of infants in the first year of life. METHODS: 100 infants were selected randomly from the population. Each infant had a single blood and urine sample taken. Antimony was assayed using inductively coupled plasma mass spectrometry. RESULTS: The reference range for antimony in the serum of infants in the first year of life was established as 0.09-0.25 microgram/l. The upper 95% centile for urinary antimony, corrected for creatinine, in the same population was 2.6 ng/mg creatinine. There was a very weak correlation between the serum and urine concentrations. CONCLUSIONS: This study confirms the presence of low concentrations of antimony in the serum and urine of healthy infants.
ISSN:0021-9746
1472-4146
DOI:10.1136/jcp.51.3.238