Anomalous results using countercurrent immunoelectrophoresis for the detection of pneumococcal antigen in Bactec blood culture media

On examination of Bactec blood cultures for pneumococcal antigen by countercurrent immunoelectrophoresis the consistent presence of a non-specific protein band caused problems with the interpretation of results, even in laboratories experienced in performing countercurrent immunoelectrophoresis. Whe...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of clinical pathology 1984-05, Vol.37 (5), p.571-572
Hauptverfasser: Chiang, W C, Tillotson, G S, Keaney, M G, Ganguli, L A
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:On examination of Bactec blood cultures for pneumococcal antigen by countercurrent immunoelectrophoresis the consistent presence of a non-specific protein band caused problems with the interpretation of results, even in laboratories experienced in performing countercurrent immunoelectrophoresis. When the Bactec blood culture system is used, countercurrent immunoelectrophoresis should not be relied on for the detection of pneumococcal antigen.