A novel option for treatment of primary axillary hyperhidrosis: fractionated microneedle radiofrequency

[10] The mechanism of reduced hyperhidrosis by way of the radiofrequency device is that the sweat glands are destroyed by heating the interface where they are located, that is, the hypodermal interface. [...]the device works by heating and cooling at the same time. There was no significant histopath...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of postgraduate medicine 2015-04, Vol.61 (2), p.141-143
Hauptverfasser: Fatemi Naeini, F, Pourazizi, M, Abtahi-Naeini, B, Nilforoushzadeh, M A, Najafian, J
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:[10] The mechanism of reduced hyperhidrosis by way of the radiofrequency device is that the sweat glands are destroyed by heating the interface where they are located, that is, the hypodermal interface. [...]the device works by heating and cooling at the same time. There was no significant histopathologic evidence of adverse effects on other cutaneous structures in this study. [...]FMR can be considered as a safe, effective and non-invasive technique for treatment of primary axillary hyperhidrosis but more studies are needed to confirm the persistent effect and histopathological alternation during treatment with FMR.
ISSN:0022-3859
0972-2823
DOI:10.4103/0022-3859.153111