Chagas disease has spread to areas that are nonendemic for the disease with human migration. Since no single reference standard test is available, serological diagnosis of chronic Chagas disease requires at least two tests. New-generation techniques have significantly improved the accuracy of Chagas...
Gespeichert in:
Veröffentlicht in: | Journal of clinical microbiology 2016-06, Vol.54 (6), p.1566-1572 |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Chagas disease has spread to areas that are nonendemic for the disease with human migration. Since no single reference standard test is available, serological diagnosis of chronic Chagas disease requires at least two tests. New-generation techniques have significantly improved the accuracy of Chagas disease diagnosis by the use of a large mixture of recombinant antigens with different detection systems, such as chemiluminescence. The aim of the present study was to assess the overall accuracy of a new-generation kit, the Architect Chagas (cutoff, ≥1 sample relative light units/cutoff value [S/CO]), as a single technique for the diagnosis of chronic Chagas disease. The Architect Chagas showed a sensitivity of 100% (95% confidence interval [CI], 99.5 to 100%) and a specificity of 97.6% (95% CI, 95.2 to 99.9%). Five out of six false-positive serum samples were a consequence of cross-reactivity with Leishmania spp., and all of them achieved results of |
---|---|