Effect of different synthetic membranes on laboratory parameters and survival in chronic haemodialysis patients

Background. A number of studies suggested that the type of dialysis membrane is associated with differences in long-term outcome of patients undergoing haemodialysis, both in terms of morbidity and mortality. In the majority of dialysis units, synthetic membranes are being used. However, no studies...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinical kidney journal 2010-05, Vol.3 (suppl_1), p.i12-i19
Hauptverfasser: Kreusser, Wilhelm, Reiermann, Stefanie, Vogelbusch, Gert, Bartual, Josè, Schulze-Lohoff, Eckhard
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background. A number of studies suggested that the type of dialysis membrane is associated with differences in long-term outcome of patients undergoing haemodialysis, both in terms of morbidity and mortality. In the majority of dialysis units, synthetic membranes are being used. However, no studies are available so far for comparison between different biocompatible membranes. Therefore, we studied the influence of high- and low-flux polysulphone membranes (PS) in comparison with polymethylmethacrylate (PMMA) membranes on mortality and morbidity on the basis of various laboratory parameters. Methods. In a cohort study, data of 260 consecutive haemodialysis patients entering our dialysis unit in the years 2003–07 were collected, comparing 435 PS patient-years and 85 PMMA patient-years. PMMA membranes (n = 33) were used for those patients who did not tolerate (e.g. for pruritus) PS membranes (n = 227). Low-flux dialysers (n = 233) were compared with high-flux (n = 37). Laboratory values were evaluated by unpaired t-test, and mortality was evaluated by log-rank test and Cox regression analysis adjusted for age, diabetes and laboratory parameters. Results. Patients in our dialysis unit had a high cardiovascular risk as demonstrated by a proportion of 63% of peripheral arterial disease. Despite this, cumulative survival was almost 60% after 5 years on dialysis. It was slightly but not significantly higher in patients on PMMA (68%) compared with PS dialysers (54%) and on high-flux (61%) versus low-flux membranes (54%). After accounting for the confounding effect of age and diabetes in the multivariate Cox regression analysis, there was no impact of the membranes used (high- or low-flux, PMMA or PS) on survival. Only age at the onset of dialysis showed a significant influence on survival (P ≤ 0.001). Independent predictors of mortality in all patients in the multivariate Cox regression analysis were age, haemoglobin, leucocytes, C-reactive protein (CRP) and creatinine. Laboratory parameters between the high- and low- flux groups were not different. PS-treated patients showed significantly (P ≤ 0.05) higher values for leucocytes, thrombocytes, ferritin, and CRP and lower values for haemoglobin, transferrin, creatinine, uric acid, creatine kinase (CK), and sodium than PMMA-treated patients. Irrespective of the membrane used, in deceased patients, the following laboratory values were higher than for patients alive: leucocytes, thrombocytes, ferritin and CRP; the foll
ISSN:2048-8505
1753-0784
2048-8513
1753-0792
DOI:10.1093/ndtplus/sfq032