Multiplex Antibody Detection for Noninvasive Genus-Level Diagnosis of Prosthetic Joint Infection
We developed and evaluated a multiplex antibody detection-based immunoassay for the diagnosis of prosthetic joint infections (PJIs). Sixteen protein antigens from three Staphylococcusspecies (Staphylococcus aureus,Staphylococcus epidermidis, and Staphylococcus lugdunensis) (8 antigens),Streptococcus...
Gespeichert in:
Veröffentlicht in: | Journal of clinical microbiology 2016-04, Vol.54 (4), p.1065-1073 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We developed and evaluated a multiplex antibody detection-based immunoassay for the diagnosis of prosthetic joint infections (PJIs). Sixteen protein antigens from three Staphylococcusspecies (Staphylococcus aureus,Staphylococcus epidermidis, and Staphylococcus lugdunensis) (8 antigens),Streptococcus agalactiae(4 antigens), and Propionibacterium acnes(4 antigens) were selected by comparative immune proteomics using serum samples from PJI cases versus controls. A bead-based multiplex immunoassay that measured serum IgG against purified, recombinant forms of each of the 16 antigens was developed. We conducted a prospective study to evaluate the performance of the assay. A PJI was defined by the presence of a sinus tract and/or positive intraoperative sample cultures (at least one sample yielding a virulent organism or at least two samples yielding the same organism). A total of 455 consecutive patients undergoing revision or resection arthroplasty (hip, 66.3%; knee, 29.7%; shoulder, 4%) at two French reference centers for the management of PJI were included: 176 patients (38.7%) were infected and 279 (61.3%) were not. About 60% of the infections involved at least one of the species targeted by the assay. The sensitivity/specificity values were 72.3%/80.7% for targeted staphylococci, 75%/92.6% forS. agalactiae, and 38.5%/84.8% forP. acnes The assay was more sensitive for infections occurring >3 months after arthroplasty and for patients with an elevated C-reactive protein (CRP) or erythrocyte sedimentation rate (ESR). However, it detected 64.3% and 58.3% of targeted staphylococcal infections associated with normal CRP and ESR values, respectively. This new multiplex immunoassay approach is a novel noninvasive tool to evaluate patients suspected of having PJIs and provides information complementary to that from inflammatory marker values. |
---|---|
ISSN: | 0095-1137 1098-660X |
DOI: | 10.1128/JCM.02885-15 |