High Rates of Occult Infection after Shoulder Fracture Fixation: Considerations for Conversion Shoulder Arthroplasty

Background Existing hardware may contribute to increased risk of bacterial contamination and subsequent periprosthetic joint infection (PJI) in conversion shoulder arthroplasty performed for failed fracture fixation. Questions/Purposes This study examined the incidence of positive pre-operative aspi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:HSS journal 2015-10, Vol.11 (3), p.198-203
Hauptverfasser: Klatte, Till O., Sabihi, Reza, Guenther, Daniel, Kamath, Atul F., Rueger, Johannes M., Gehrke, Thorsten, Kendoff, Daniel
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background Existing hardware may contribute to increased risk of bacterial contamination and subsequent periprosthetic joint infection (PJI) in conversion shoulder arthroplasty performed for failed fracture fixation. Questions/Purposes This study examined the incidence of positive pre-operative aspiration and inflammatory marker data, along with correlation of pre-operative positive aspiration or inflammatory markers and subsequent infection following conversion shoulder arthroplasty for failed open reduction and internal fixation (ORIF) and the need for re-operation at 4.6-year follow-up. Methods Twenty-eight patients who underwent conversion to shoulder arthroplasty for any reason after fracture fixation were retrospectively reviewed in a single center. A pre-operative aspiration was done in 17 patients; all patients had intra-operative tissue sampling. All procedures were single-stage removal of hardware and performance of the arthroplasty. In cases of pre-operative positive bacterial growth, a single-stage procedure was performed according to the septic ENDO-Klinik protocol. Results In 4 of 17 pre-operative joint aspirations, bacterial growth was detected; one pre-operative negative aspiration demonstrated bacterial growth in intra-operative sampling. In three of them, the infection has been validated through intra-operatively results. Pre-operative aspiration showed a sensitivity of 75% and specificity of 92% (p < 0.005) for infection. No post-operative PJIs were observed. Six revisions were performed, most commonly for aseptic loosening (two cases) and conversion of hemiarthroplasty to a reverse design (two cases). Conclusions In conclusion, the risk of low-grade shoulder infection after fracture osteosynthesis may be higher than in hip and knee joints, based on limited study data. Adequate pre-operative testing is recommended to rule out occult shoulder infection in this setting.
ISSN:1556-3316
1556-3324
DOI:10.1007/s11420-015-9450-z