Concentration of Sonication Fluid through Centrifugation Is Superior to Membrane Filtration for Microbial Diagnosis of Orthopedic Implant-Associated Infection

Microbial identification of orthopedic implant-associated infections using sonication fluid (SF) submitted to a concentration step by membrane filtration (SMF) was compared with the standard centrifugation (SC) method. Among 33 retrieved infected implants, sonication identified microorganisms in 26...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of clinical microbiology 2016-03, Vol.54 (3), p.788-790
Hauptverfasser: Zitron, Renato, Wajsfeld, Tali, Klautau, Giselle Burlamaqui, da Silva, Cely Barreto, Nigro, Stanley, Mercadante, Marcelo Tomanik, Polesello, Giancarlo Cavalli, Cury, Ricardo de Paula Leite, Salles, Mauro Jose Costa
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Microbial identification of orthopedic implant-associated infections using sonication fluid (SF) submitted to a concentration step by membrane filtration (SMF) was compared with the standard centrifugation (SC) method. Among 33 retrieved infected implants, sonication identified microorganisms in 26 (78.8%). The sensitivity of SC was higher than that of SMF (78.8% versus 30.3%; P < 0.001).