Performance of Xpert MTB/RIF Assay in Diagnosis of Pleural Tuberculosis by Use of Pleural Fluid Samples
Prospectively, 162 pleural fluid samples from patients with probable tuberculous pleural effusion were tested by the Xpert MTB/RIF assay and the Bactec MGIT-960 culture system. Of these, 43 (26.5%) were positive in the MGIT-960 culture, and 23 (14.2%), in the Xpert MTB/RIF assay. The sensitivity and...
Gespeichert in:
Veröffentlicht in: | Journal of clinical microbiology 2015-11, Vol.53 (11), p.3636-3638 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Prospectively, 162 pleural fluid samples from patients with probable tuberculous pleural effusion were tested by the Xpert MTB/RIF assay and the Bactec MGIT-960 culture system. Of these, 43 (26.5%) were positive in the MGIT-960 culture, and 23 (14.2%), in the Xpert MTB/RIF assay. The sensitivity and specificity of the Xpert MTB/RIF compared with the MGIT-960 culture were 54.8% and 100%, respectively. |
---|---|
ISSN: | 0095-1137 1098-660X |
DOI: | 10.1128/JCM.02182-15 |