Performance of Xpert MTB/RIF Assay in Diagnosis of Pleural Tuberculosis by Use of Pleural Fluid Samples

Prospectively, 162 pleural fluid samples from patients with probable tuberculous pleural effusion were tested by the Xpert MTB/RIF assay and the Bactec MGIT-960 culture system. Of these, 43 (26.5%) were positive in the MGIT-960 culture, and 23 (14.2%), in the Xpert MTB/RIF assay. The sensitivity and...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of clinical microbiology 2015-11, Vol.53 (11), p.3636-3638
Hauptverfasser: Rufai, Syed Beenish, Singh, Amit, Kumar, Parveen, Singh, Jitendra, Singh, Sarman
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Prospectively, 162 pleural fluid samples from patients with probable tuberculous pleural effusion were tested by the Xpert MTB/RIF assay and the Bactec MGIT-960 culture system. Of these, 43 (26.5%) were positive in the MGIT-960 culture, and 23 (14.2%), in the Xpert MTB/RIF assay. The sensitivity and specificity of the Xpert MTB/RIF compared with the MGIT-960 culture were 54.8% and 100%, respectively.
ISSN:0095-1137
1098-660X
DOI:10.1128/JCM.02182-15