The accuracy of presepsin (sCD14-ST) for the diagnosis of sepsis in adults: a meta-analysis

The early diagnosis of sepsis remains a challenge. Recently, soluble cluster of differentiation 14 subtype (sCD14-ST), also known as presepsin, has been identified as a potential biomarker of sepsis. We performed a meta-analysis to assess the diagnostic accuracy of presepsin for sepsis in patients w...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Critical care (London, England) England), 2015-09, Vol.19 (1), p.323-323, Article 323
Hauptverfasser: Zhang, Xin, Liu, Dan, Liu, You-Ning, Wang, Rui, Xie, Li-Xin
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The early diagnosis of sepsis remains a challenge. Recently, soluble cluster of differentiation 14 subtype (sCD14-ST), also known as presepsin, has been identified as a potential biomarker of sepsis. We performed a meta-analysis to assess the diagnostic accuracy of presepsin for sepsis in patients with systemic inflammation. We systematically searched the PubMed, Embase, Web of Knowledge and Cochrane databases. Studies were included if they assessed the diagnostic accuracy of presepsin for sepsis in adult patients with systemic inflammatory response syndrome (SIRS). Furthermore, a 2 × 2 contingency table was constructed based on these results. Two authors independently judged the studies and extracted the data. The diagnostic accuracy of presepsin in sepsis was calculated using a bivariate meta-analysis model. The Q-test and I (2) index were used to test the heterogeneity. Eight studies involving a total of 1,815 patients were included in the present study. The pooled sensitivity, specificity, diagnostic odds ratio, positive likelihood ratio and negative likelihood ratio were 0.86 (95% CI: 0.79-0.91), 0.78 (95% CI: 0.68-0.85), 22 (95% CI: 10-48), 3.8 (95% CI: 2.6-5.7), and 0.18 (95% CI: 0.11-0.28), respectively. The area under the summary receiver operator characteristic curve was 0.89 (95% CI: 0.86-0.92). Meta-regression analysis revealed that consecutive patient selection, sample size and setting significantly accounted for the heterogeneity of sensitivity. Our findings suggest that presepsin exhibits very good diagnostic accuracy (AUC=0.89) for the diagnosis for sepsis. Nevertheless, an overall assessment of all the clinical indexes for sepsis diagnosis and continual re-evaluation of presepsin during the course of the disease are needed.
ISSN:1364-8535
1466-609X
1364-8535
1366-609X
DOI:10.1186/s13054-015-1032-4