Sequential argon-YAG laser membranotomy of extensive persistent pupillary membrane with visual loss
A 20-year-old woman, a registered nurse, presented with best-corrected visual acuity of 6/15 (20/50) due to bilateral extensive persistent pupillary membrane. Sequential argon laser photocoagulation of the iris strands at the pupillary membrane iris collarette followed by neodymium:YAG laser lysis r...
Gespeichert in:
Veröffentlicht in: | BMJ case reports 2015-08, Vol.2015, p.bcr2015210140 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A 20-year-old woman, a registered nurse, presented with best-corrected visual acuity of 6/15 (20/50) due to bilateral extensive persistent pupillary membrane. Sequential argon laser photocoagulation of the iris strands at the pupillary membrane iris collarette followed by neodymium:YAG laser lysis resulted in partial clearing of the central visual axis without bleeding. Best-corrected visual acuity improved to 6/9 (20/30) bilaterally without complications noted 1 year after combined laser therapy. |
---|---|
ISSN: | 1757-790X 1757-790X |
DOI: | 10.1136/bcr-2015-210140 |