Rotor Stability Separates Sustained Ventricular Fibrillation From Self-Terminating Episodes in Humans

Objectives This study mapped human ventricular fibrillation (VF) to define mechanistic differences between episodes requiring defibrillation versus those that spontaneously terminate. Background VF is a leading cause of mortality; yet, episodes may also self-terminate. We hypothesized that the initi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of the American College of Cardiology 2014-06, Vol.63 (24), p.2712-2721
Hauptverfasser: Krummen, David E., MD, Hayase, Justin, MD, Morris, David J., MD, Ho, Jeffrey, MD, Smetak, Miriam R., BS, Clopton, Paul, MS, Rappel, Wouter-Jan, PhD, Narayan, Sanjiv M., MD, PhD
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Objectives This study mapped human ventricular fibrillation (VF) to define mechanistic differences between episodes requiring defibrillation versus those that spontaneously terminate. Background VF is a leading cause of mortality; yet, episodes may also self-terminate. We hypothesized that the initial maintenance of human VF is dependent upon the formation and stability of VF rotors. Methods We enrolled 26 consecutive patients (age 64 ± 10 years, n = 13 with left ventricular dysfunction) during ablation procedures for ventricular arrhythmias, using 64-electrode basket catheters in both ventricles to map VF prior to prompt defibrillation per the institutional review board–approved protocol. A total of 52 inductions were attempted, and 36 VF episodes were observed. Phase analysis was applied to identify biventricular rotors in the first 10 s or until VF terminated, whichever came first (11.4 ± 2.9 s to defibrillator charging). Results Rotors were present in 16 of 19 patients with VF and in all patients with sustained VF. Sustained, but not self-limiting VF, was characterized by greater rotor stability: 1) rotors were present in 68 ± 17% of cycles in sustained VF versus 11 ± 18% of cycles in self-limiting VF (p < 0.001); and 2) maximum continuous rotations were greater in sustained (17 ± 11, range 7 to 48) versus self-limiting VF (1.1 ± 1.4, range 0 to 4, p < 0.001). Additionally, biventricular rotor locations in sustained VF were conserved across multiple inductions (7 of 7 patients, p = 0.025). Conclusions In patients with and without structural heart disease, the formation of stable rotors identifies individuals whose VF requires defibrillation from those in whom VF spontaneously self-terminates. Future work should define the mechanisms that stabilize rotors and evaluate whether rotor modulation may reduce subsequent VF risk.
ISSN:0735-1097
1558-3597
DOI:10.1016/j.jacc.2014.03.037