The early plasma concentration of 51Cr-EDTA in patients with cirrhosis and ascites: a comparison of three models

OBJECTIVESThe aim of the study was to determine which of three two-parameter fitting functions (exponential, linear-log, and negative-power function of time) most accurately models early chromium-51-EDTA (Cr-EDTA) plasma concentration data prior to 120 min in patients with cirrhosis and ascites and...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Nuclear medicine communications 2015-04, Vol.36 (4), p.392-397
Hauptverfasser: Wanasundara, Surajith N, Wesolowski, Michal J, Puetter, Richard C, Burniston, Maria T, Xirouchakis, Elias, Giamalis, Ioannis G, Babyn, Paul S, Wesolowski, Carl A
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:OBJECTIVESThe aim of the study was to determine which of three two-parameter fitting functions (exponential, linear-log, and negative-power function of time) most accurately models early chromium-51-EDTA (Cr-EDTA) plasma concentration data prior to 120 min in patients with cirrhosis and ascites and understand how these fitting functions affect the calculation of the area under the plasma concentration curve (AUC). METHODSA bolus, antecubital intravenous injection of 2.6 MBq of Cr-EDTA was given to 13 patients with cirrhosis and ascites. Up to 16 blood samples were drawn at time points ranging from 5 to 1440 min following injection. The concentration data prior to 120 min were used as reference data. Early time concentration values, estimated by fitting exponential, linear-log, and negative-power functions of time to the time samples at 120, 180, and 240 min, were then compared with reference data. The AUC was calculated for each patient using the exponential, Bröchner-Mortensen-corrected exponential, and linear-log functions, and these values were compared. RESULTSThe withheld, observed plasma concentrations were (a) most accurately estimated by linear-log functions (Wilcoxon P=0.4548), (b) significantly underestimated by exponential functions (Wilcoxon P=0.0002), and (c) significantly overestimated by negative-power functions (Wilcoxon P=0.0034). The relative errors when ranked from best to worst were those for the linear-log (12.0%, 9.0%), exponential (22.9%, 14.2%), and negative-power (31.9%, 48.4%) functions of time, respectively (median, interquartile range). For each patient, the values for AUC calculated by the exponential function differed significantly (range=3.4–15.3%, median=8.3%) from those calculated by the corrected Bröchner-Mortensen exponential, as to a lesser extent did those values calculated using linear-log functions (range=0.4–8.0%, median=3.0%). CONCLUSIONIn patients with cirrhosis, linear-log functions were significantly more accurate than exponential or power functions in estimating early time plasma concentrations (
ISSN:0143-3636
1473-5628