Closure of Oroantral Fistula Using Titanium Plate with Transalveolar Wiring
Background Alloplastic materials such as tantalum, gold plates and foils, hydroxyapatite blocks have been used for closure of oroantral fistula (OAF). However, these materials are not widely accepted in routine surgical closure of OAF due to cost, difficult handling, increased rate of infection, and...
Gespeichert in:
Veröffentlicht in: | Journal of maxillofacial and oral surgery 2015-03, Vol.14 (1), p.121-125 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background
Alloplastic materials such as tantalum, gold plates and foils, hydroxyapatite blocks have been used for closure of oroantral fistula (OAF). However, these materials are not widely accepted in routine surgical closure of OAF due to cost, difficult handling, increased rate of infection, and exfoliation.
Purpose
To overcome the above drawbacks this study aimed to use titanium plates (0.3 mm) with transalveolar wiring fixation for closure of OAF.
Patients and Methods
Ten patients with OAFs who consented to undergo this trial were selected and treated under an outpatient basis in the Oral Surgery Department, Faculty of Dentistry, Mansoura University, Egypt.
Results
All OAFs were successfully treated with no eventful complications.
Conclusion
This study concludes that titanium plates with transalveolar wiring fixation is an excellent technique for closure of OAF. The high success rate with this technique warrants its use for closure of OAF. |
---|---|