Five microRNAs in plasma as novel biomarkers for screening of early-stage non-small cell lung cancer

In order to find novel noninvasive biomarkers with high accuracy for the screening of early-stage non-small cell lung cancer (NSCLC), we investigate the predictive power of 5 microRNAs (miR-20a, miR-145, miR-21, miR223 and miR-221) as potential biomarkers in early-stage NSCLC. In training set, 25 ea...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Respiratory research 2014-11, Vol.15 (1), p.149-149, Article 149
Hauptverfasser: Geng, Qing, Fan, Tao, Zhang, Boyou, Wang, Wei, Xu, Yao, Hu, Hao
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In order to find novel noninvasive biomarkers with high accuracy for the screening of early-stage non-small cell lung cancer (NSCLC), we investigate the predictive power of 5 microRNAs (miR-20a, miR-145, miR-21, miR223 and miR-221) as potential biomarkers in early-stage NSCLC. In training set, 25 early-stage NSCLC patients and 25 matched healthy controls are included to assess the miRNA expression profile between early-stage NSCLC patients and healthy controls by real-time RT-PCR. We found that five of these miRNAs (miR-20a, miR-223, miR-21, miR-221 and miR-145) levels in NSCLC patients were significantly dysregulated compared with the healthy groups and thus were selected to validation set. Therefore, a validation experiment was further performed to investigate the potential predictive power of these five miRNAs based on 126 early-stage NSCLC patients, 42 NCPD patients and 60 healthy controls. The receiver operating characteristic (ROC) curves were generated for the five miRNAs. ROC curve analyses suggested that these five plasma miRNAs could be promising biomarkers for NSCLC, with relatively high AUC values as follows: miR-20a, 0.89 with 95% CI of [0.85-0.93]; miR-223, 0.94 with 95% CI of [0.91-0.96]; miR-21, 0.77 with 95% CI of [0.71-0.83]; miR-155, 0.92 with 95% CI of [0.89-0.96]; miR-145, 0.77 with 95% CI of [0.71-0.83]. Stratified analyses indicated that plasma miR-20a, miR-223, miR-21 and miR-145 showed better predictive value in smokers than in non-smokers, while miR-155 might be more suitable for non-smokers. In addition, all of these five miRNAs could differentiate NSCLC from controls with a higher accuracy in advanced stage and squamous carcinoma subgroups. In conclusion, our study suggested that five plasma miRNAs (miR-20a, miR-145, miR-21, miR-223 and miR-221) can be used as promising biomarkers in early screening of NSCLC. Nevertheless, further validation and optimizing improvement should be performed on larger sample to confirm our results.
ISSN:1465-993X
1465-9921
1465-993X
1465-9921
DOI:10.1186/s12931-014-0149-3