The MAGEC System for Spinal Lengthening in Children with Scoliosis: A NICE Medical Technology Guidance

Scoliosis—structural lateral curvature of the spine—affects around four children per 1,000. The MAGEC system comprises a magnetically distractible spinal rod implant and an external remote controller, which lengthens the rod; this system avoids repeated surgical lengthening. Rod implants brace the s...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied health economics and health policy 2014-12, Vol.12 (6), p.587-599
Hauptverfasser: Jenks, Michelle, Craig, Joyce, Higgins, Joanne, Willits, Iain, Barata, Teresa, Wood, Hannah, Kimpton, Christine, Sims, Andrew
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Scoliosis—structural lateral curvature of the spine—affects around four children per 1,000. The MAGEC system comprises a magnetically distractible spinal rod implant and an external remote controller, which lengthens the rod; this system avoids repeated surgical lengthening. Rod implants brace the spine internally and are lengthened as the child grows, preventing worsening of scoliosis and delaying the need for spinal fusion. The Medical Technologies Advisory Committee at the National Institute for Health and Care Excellence (NICE) selected the MAGEC system for evaluation in a NICE medical technologies guidance. Six studies were identified by the sponsor (Ellipse Technologies Inc.) as being relevant to the decision problem. Meta-analysis was used to compare the clinical evidence results with those of one conventional growth rod study, and equal efficacy of the two devices was concluded. The key weakness was selection of a single comparator study. The External Assessment Centre (EAC) identified 16 conventional growth rod studies and undertook meta-analyses of relevant outcomes. Its critique highlighted limitations around study heterogeneity and variations in baseline characteristics and follow-up duration, precluding the ability to draw firm conclusions. The sponsor constructed a de novo costing model showing that MAGEC rods generated cost savings of £9,946 per patient after 6 years, compared with conventional rods. The EAC critiqued and updated the model structure and inputs, calculating robust cost savings of £12,077 per patient with MAGEC rods compared with conventional rods over 6 years. The year of valuation was 2012. NICE issued a positive recommendation as supported by the evidence (Medical Technologies Guidance 18).
ISSN:1175-5652
1179-1896
1179-1896
DOI:10.1007/s40258-014-0127-4