Clinical outcomes after cataract surgery with implantation of the Tecnis ZMB00 multifocal intraocular lens

The aim of this study was to evaluate visual performance, contrast sensitivity, and patient satisfaction in patients undergoing cataract surgery with bilateral implantation of the Tecnis ZMB00 diffractive multifocal IOL (intraocular lens). This was a prospective study of 40 eyes of 20 patients with...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Medical science monitor 2014-07, Vol.20, p.1220-1226
Hauptverfasser: Lubiński, Wojciech, Gronkowska-Serafin, Jolanta, Podborączyńska-Jodko, Karolina
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The aim of this study was to evaluate visual performance, contrast sensitivity, and patient satisfaction in patients undergoing cataract surgery with bilateral implantation of the Tecnis ZMB00 diffractive multifocal IOL (intraocular lens). This was a prospective study of 40 eyes of 20 patients with an age range from 48 to 67 years and undergoing cataract surgery with implantation of the diffractive 1-piece IOL Tecnis ZMB00 (Abbott Medical Optics) in 1 eye and 3 weeks later in the other eye. The following parameters were evaluated at 3 and 6 months after the operation: binocular uncorrected distance, intermediate and near visual acuity (UDVA, UIVA, UNVA), uncorrected binocular photopic and mesopic distance and photopic near contrast sensitivity (CSV-1000), subjective symptoms, and patient satisfaction (VF-14). No significant change was observed in logMAR UDVA between 3 and 6 months postoperatively (-0.11±0.14 vs. -0.10±0.13, p>0.05). In contrast, UNVA (0.06±0.12 vs. -0.02±0.12, p=0.004) and UIVA (0.12±0.15 vs. 0.07±0.11, p=0.005) in this period improved significantly. At 3 and 6 months after surgery, 85% of patients no longer needed to wear corrective lenses. Contrast sensitivity under different conditions was within normal age-matched limits, with significant improvements for some spatial frequencies at 3 and 6 months after surgery (p
ISSN:1643-3750
1234-1010
1643-3750
DOI:10.12659/MSM.890585