A Prospective Randomized Clinical Trial Comparing 3D and Standard Miniplates in Treatment of Mandibular Symphysis and Parasymphysis Fractures
Purpose To compare the efficacy of the 3D miniplates to standard miniplates in the osteosynthesis of mandibular symphysis and parasymphysis fractures on the basis of clinical parameters and radiographic evaluation. Patients and Methods A prospective randomized clinical trial was conducted to treat c...
Gespeichert in:
Veröffentlicht in: | Journal of maxillofacial and oral surgery 2014-06, Vol.13 (2), p.79-83 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose
To compare the efficacy of the 3D miniplates to standard miniplates in the osteosynthesis of mandibular symphysis and parasymphysis fractures on the basis of clinical parameters and radiographic evaluation.
Patients and Methods
A prospective randomized clinical trial was conducted to treat consecutive mandibular symphysis and parasymphysis fractures. The patients were randomly divided into 2 groups. The patients underwent osteosynthesis in group A with 3D titanium miniplates and in group B with conventional titanium miniplates. The cause of trauma, the number of days from injury to surgery, average age and gender were all reviewed. The assessment of the patients was done at 1, 3, and 6 weeks and 3 months using the clinical parameters and radiographic evaluation.
Results
Eighty patients with isolated symphysis or parasymphysis fracture met the inclusion criteria. In our study, a statistically significant difference was not found in the clinical parameters such as pain, swelling, infection, paresthesia, hardware failure, and mobility between the fracture segments. Similarly Radiological evaluation did not show any statistically significant difference in reduction between the 2 groups. 3D plates are difficult to adapt and use sometimes, but operative time is less with them in treatment of symphysis and parasymphysis fractures.
Conclusion
The use of 3D miniplates for symphysis and parasymphysis fracture fixation was efficacious enough to bear the masticatory load during osteosynthesis of the fracture. Although 3D miniplate system is difficult to adapt and difficult to use in cases of fractures involving the mental nerve, they provide the advantage of less operative time and less implant material in treatment of symphysis and parasymphysis fracture, with clinical results almost similar to those seen with conventional miniplate osteosynthesis. |
---|---|
ISSN: | 0972-8279 0974-942X |
DOI: | 10.1007/s12663-013-0483-x |