Validity and reliability of the Short Physical Performance Battery (SPPB): a pilot study on mobility in the Colombian Andes
Objectives: To assess the validity (convergent and construct) and reliability of the Short Physical Performance Battery (SPPB) among non-disabled adults between 65 to 74 years of age residing in the Andes Mountains of Colombia. Methods: Design: Validation study; Participants: 150 subjects aged 65 to...
Gespeichert in:
Veröffentlicht in: | Colombia medica (Cali, Colombia) Colombia), 2013-07, Vol.44 (3), p.165-171 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Objectives: To assess the validity (convergent and construct) and
reliability of the Short Physical Performance Battery (SPPB) among
non-disabled adults between 65 to 74 years of age residing in the Andes
Mountains of Colombia. Methods: Design: Validation study; Participants:
150 subjects aged 65 to 74 years recruited from elderly associations
(day-centers) in Manizales, Colombia. Measurements: The SPPB tests of
balance, including time to walk 4 meters and time required to stand
from a chair 5 times were administered to all participants. Reliability
was analyzed with a 7-day interval between assessments and use of
repeated ANOVA testing. Construct validity was assessed using factor
analysis and by testing the relationship between SPPB and depressive
symptoms, cognitive function, and self rated health (SRH), while the
concurrent validity was measured through relationships with mobility
limitations and disability in Activities of Daily Living (ADL). ANOVA
tests were used to establish these associations. Results: Test-retest
reliability of the SPPB was high: 0.87 (CI95%: 0.77-0.96). A one factor
solution was found with three SPPB tests. SPPB was related to
self-rated health, limitations in walking and climbing steps and to
indicators of disability, as well as to cognitive function and
depression. There was a graded decrease in the mean SPPB score with
increasing disability and poor health. Conclusion: The Spanish version
of SPPB is reliable and valid to assess physical performance among
older adults from our region. Future studies should establish their
clinical applications and explore usage in population studies.
Objetivos: Evaluar la validez convergente y de constructo, y la
confiabilidad de la Batería Corta de desempeño físico
(Short Physical Performance Battery -SPPB-) entre ancianos no
discapacitados entre 65 a 74 años, en los Andes Colombianos.
Métodos: 150 ancianos entre 65-74 años reclutados de los
centros-día de la ciudad de Manizales, Colombia. Las pruebas del
SPPB: equilibrio, caminar 4 m. y el tiempo para incorporarse 5 veces de
una silla se aplicaron a todos los participantes. La fiabilidad fue
medida con un intervalo de 7 días entre las evaluaciones, y
analizada con Anova de medidas repetidas. La validez de constructo fue
evaluada mediante análisis factorial y relaciones entre el SPPB
con la función cognoscitiva, síntomas de depresión,
auto-percepción de salud, y factores sociales; y la validez
convergente mediante asociaciones con las limitaci |
---|---|
ISSN: | 0120-8322 1657-9534 |
DOI: | 10.25100/cm.v44i3.1181 |