Acute double flexor tendon ruptures following injection of collagenase clostridium histolyticum (Xiapex) for Dupuytren's contracture

We report a case of acute (24 h) double flexor tendon rupture of the little finger after a single injection of collagenase clostridium histolyticum into a palmar Dupuytren's contracture cord which caused metacarpophalangeal joint contracture. Tendon surgery was performed 48 h postinjury with pr...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:BMJ case reports 2014-04, Vol.2014, p.bcr2013203338
Hauptverfasser: Povlsen, Bo, Singh, Sarvpreet
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We report a case of acute (24 h) double flexor tendon rupture of the little finger after a single injection of collagenase clostridium histolyticum into a palmar Dupuytren's contracture cord which caused metacarpophalangeal joint contracture. Tendon surgery was performed 48 h postinjury with primary repair and standard rehabilitation but it resulted in poor active flexion due to adhesions. Previous papers have suggested that a needle inserted into the flexor tendon can be detected prior to the injection of collagenase by asking the patient to actively move the finger, but our test on an awake patient showed that when a 27-gauge needle was inserted into the flexor tendons through a thick palmar cord, the syringe did not move significantly when the patient moved the finger, and therefore this test does not minimise the risk of iatrogenic tendon injury when using collagenase (Xiapex) for Dupuytren's contracture.
ISSN:1757-790X
1757-790X