Everolimus- and sirolimus-eluting stents in patients with and without ST-segment elevation myocardial infarction
Aims Everolimus-eluting stents (EES) were superior to sirolimus-eluting stents (SES) in a dedicated myocardial infarction trial, a finding that was not observed in trials with low percentages of ST-elevation myocardial infarction (STEMI). Therefore, this study sought to investigate the influence of...
Gespeichert in:
Veröffentlicht in: | Netherlands heart journal 2014-04, Vol.22 (4), p.167-173 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Aims
Everolimus-eluting stents (EES) were superior to sirolimus-eluting stents (SES) in a dedicated myocardial infarction trial, a finding that was not observed in trials with low percentages of ST-elevation myocardial infarction (STEMI). Therefore, this study sought to investigate the influence of clinical presentation on outcome after EES and SES implantation.
Methods
A pooled population of 1602 randomised patients was formed from XAMI (acute MI trial) and APPENDIX-AMI (all-comer trial). Primary outcome was cardiac mortality, MI and target vessel revascularisation at 2 years. Secondary endpoints included definite/probable stent thrombosis (ST). Adjustment was done using Cox regression.
Results
In total, 902 EES and 700 SES patients were included, of which 44 % STEMI patients (EES 455; SES 257) and 56 % without STEMI (EES 447; SES 443). In the pooled population, EES and SES showed similar outcomes during follow-up. Moreover, no differences in the endpoints were observed after stratification according to presentation. Although a trend toward reduced early definite/probable ST was observed in EES compared with SES in STEMI patients, long-term ST rates were low and comparable.
Conclusions
EES and SES showed a similar outcome during 2-year follow-up, regardless of clinical presentation. Long-term safety was excellent for both devices, despite wide inclusion criteria and a large sub-population of STEMI patients. |
---|---|
ISSN: | 1568-5888 1876-6250 |
DOI: | 10.1007/s12471-014-0525-0 |