Accelerated partial breast irradiation using external beam radiotherapy—A feasibility study based on dosimetric analysis

Abstract Aim To investigate the feasibility of using External Beam radiotherapy for accelerated partial breast irradiation by a comparative tumour and normal tissue dose volume analysis with that of high dose rate interstitial brachytherapy. Background Accelerated Partial Breast Irradiation (APBI) i...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Reports of practical oncology and radiotherapy 2012, Vol.17 (4), p.200-206
Hauptverfasser: Anbumani, Surega, Palled, Siddanna R, Prabhakar, Girish S, Nambiraj, N. Arunai, Pichandi, Anchineyan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Aim To investigate the feasibility of using External Beam radiotherapy for accelerated partial breast irradiation by a comparative tumour and normal tissue dose volume analysis with that of high dose rate interstitial brachytherapy. Background Accelerated Partial Breast Irradiation (APBI) is more clinically appealing because of the reduced treatment course duration and the irradiated area. Brachytherapy application is more dependent on the clinician's expertise when it is practised free hand without image guidance and a template. It happens to be an invasive procedure with the use of local anaesthesia which adds patient discomfort apart from its cost compared to External Beam Radiotherapy. But APBI with brachytherapy is more commonly practised procedure compared to EBRT owing to its previous reults. Hence in this research study, we intend to explore the use of EBRT with the radiobiological corrections for APBI in the place of brachytherapy. It is done as a dosimetric comparison of Brachytherapy treatment plans with that of EBRT plans. Materials and methods The computed tomography images of 15 patients undergoing ISBT planning were simulated with conformal photon fields. Various dose volume parameters of each structure were obtained from the DVH generated in the brachytherapy and the simulated external beam planning which can correlate well with the late toxicity. The plan quality indices such as conformity index and homogeneity index for the target volume were computed from the dosimetric factors. The statistical p values for CI, HI and normal tissue dosimetric parameters were calculated and the confidence levels achievable were analysed. The dose prescribed in brachytherapy was 3400cGy in ten fractions. The equivalent prescription dose for the external beam radiotherapy planning was 3000cGy in five fractions applied with radiobiological correction. Results All the fifteen patients were with complete lung data and six were with left sided tumours having complete cardiac data. The lung dosimetry data and the cardiac dosimetry data of the patients were studied. Lower percentages of lung and cardiac V20 and V5 volumes were obtained with conformal planning. The conformity of radiation dose to the tumour volume was akin to the interstitial brachytherapy planning. Moreover the external beam planning resulted in more homogenous dose distribution. For the sampled population, the statistical analysis showed a confidence level of 95% for using EBRT as an al
ISSN:1507-1367
2083-4640
DOI:10.1016/j.rpor.2012.04.002