Minimally invasive osteosynthesis of adult tibia fractures by means of rigid fixation with anatomic locked plates

Main principle of biological fixation by minimally invasive locked plate osteosynthesis (MILPO) in lower extremity long bone fractures is relative stability which is provided by using long plate with limited number of screws. Some biomechanical studies have been reported about this issue. However, c...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Strategies in trauma and limb reconstruction 2013-08, Vol.8 (2), p.103-109
Hauptverfasser: Güven, Melih, Ceviz, Emrah, Demirel, Murat, Özler, Turhan, Kocadal, Onur, Önal, Ayberk
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Main principle of biological fixation by minimally invasive locked plate osteosynthesis (MILPO) in lower extremity long bone fractures is relative stability which is provided by using long plate with limited number of screws. Some biomechanical studies have been reported about this issue. However, clinical studies are still missing. The aims of this retrospective extended case series were to evaluate the clinical and radiological results of adult tibia fractures treated by MILPO and the effect of plate length and screw density on complication rates. Twenty tibia fractures in 19 patients (mean age 42.3 years) operated by MILPO were reviewed. According to the AO classification, diaphyseal and metaphyseal fractures without intraarticular extensions were simple and wedge-type fractures, whereas all intraarticular fractures were comminuted. Number of screws, cortices and empty screw holes proximal and distal to the fracture, plate-span ratio (plate length divided by overall fracture length), plate-screw density (number of inserted screws divided by number of plate holes), fixation failures, delayed or nonunion, malalignment and leg length discrepancy were documented. Mean follow-up was 16 (range 12–26) months. On average, 4 screws with 6 cortices were used both proximally and distally in all fractures. Only in diaphyseal fractures, one screw hole close to the fracture was omitted. Average plate-screw density and plate-span ratio were 0.68 and 4, respectively. Mean union time was 3 months. There were no cases of delayed or nonunion on the final follow-up. Plate bending was observed in one patient who had fair result. The remaining 18 (94.8 %) patients showed good and excellent results. Satisfactory results can be achieved despite low plate-span ratio and high plate-screw density in simple and wedge-type diaphyseal fractures of the tibia. Additionally, plate-screw density can be higher at metaphysis in intraarticular fractures, in which essential point is a perfectly stable fixation that provides early motion.
ISSN:1828-8936
1828-8928
DOI:10.1007/s11751-013-0164-9