A Novel Beads-Based Dissolution Method for the In Vitro Evaluation of Extended Release HPMC Matrix Tablets and the Correlation with the In Vivo Data

The aim of this work was to establish alternative in vitro dissolution method with good discrimination and in vivo predictability for the evaluation of HPMC extended release matrix tablets. For this purpose, two different HPMC matrix tablet formulations were first evaluated by a range of conventiona...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The AAPS journal 2013-01, Vol.15 (1), p.267-277
Hauptverfasser: Klančar, Uroš, Markun, Boštjan, Baumgartner, Saša, Legen, Igor
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The aim of this work was to establish alternative in vitro dissolution method with good discrimination and in vivo predictability for the evaluation of HPMC extended release matrix tablets. For this purpose, two different HPMC matrix tablet formulations were first evaluated by a range of conventional dissolution testing methods using apparatus 1, apparatus 2, and apparatus 3 according to US Pharmacopoeia. Obtained results showed low discrimination between the tested samples. Afterward, a novel dissolution testing method which combines plastic beads and apparatus 3 was developed with the aim to better mimic the mechanical forces that occur in vivo . Results showed that sufficiently large mechanical stress with high dips per minute program setting (apparatus 3) was needed to obtain in vitro discriminative results, which are in accordance with the in vivo data. The in vivo relevance of the method was confirmed with the establishment of the level A in vitro – in vivo correlation.
ISSN:1550-7416
1550-7416
DOI:10.1208/s12248-012-9422-x