Evaluation of acoustic radiation force impulse imaging for determination of liver stiffness using transient elastography as a reference
AIM: To evaluate cut-off values and performance of acoustic radiation force impulse imaging (ARFI) using transient elastography [FibroScan (FS)] as a reference. METHODS: Six hundred and six patients were enrolled in this study.All patients underwent liver stiffness measurement with FS (FS-LS) and AR...
Gespeichert in:
Veröffentlicht in: | World journal of gastroenterology : WJG 2012-03, Vol.18 (10), p.1077-1084 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | AIM: To evaluate cut-off values and performance of acoustic radiation force impulse imaging (ARFI) using transient elastography [FibroScan (FS)] as a reference. METHODS: Six hundred and six patients were enrolled in this study.All patients underwent liver stiffness measurement with FS (FS-LS) and ARFI (with shear wave velocity quantification; ARFI-SWV) and the performance of ARFI in comparison to FS was determined. Sixtyeight patients underwent liver biopsy. RESULTS: Significantly higher success rates for the determination of liver stiffness were found using ARFI as compared to FS [604/606 (99.7%) vs 482/606 (79.5%); P 〈 0.001]. ARFI-SWV correlated significantly with FS-LS (r = 0.920, P 〈 0.001). ARFI-SWV increased significantly with the stage of fibrosis (1.09 ± 0.13 m/s for patients with no significant fibrosis (FS-LS 〈 7.6 kPa); 1.46 ± 0.27 m/s for patients with significant liver fibrosis (7.6 〈 FS-LS ≤ 13.0 kPa); and 2.55 ± 0.77 m/s for patients with liver cirrhosis (FS-LS 〉 13.0 kPa)). ARFI-SWV cut-off values were identified for no significant fibrosis (1.29 m/s; sensitivity 91.4% and specificity 92.6%) and for liver cirrhosis (1.60 m/s; sensitivity 92.3% and specificity 96.5%). The optimal cut-off value for predicting liver fibrosis (F ≥ 2) was 1.32 m/s (sensitivity 87.0% and specificity 80.0%) and for liver cirrhosis (F4) 1.62 m/s (sensitivity 100% and specificity 85.7%), for patients who underwent liver biopsy. An excellent inter-and intraobserver reproducibility was observed for ARFI-SWV determinations. CONCLUSION: An ARFI-SWV cut-off value of 1.29 m/s seems to be optimal for patients with no significant liver fibrosis and 1.60 m/s for patients with liver cirrhosis. |
---|---|
ISSN: | 1007-9327 2219-2840 |
DOI: | 10.3748/wjg.v18.i10.1077 |