Evoked Potential Monitoring Identifies Possible Neurological Injury During Positioning for Craniotomy

Somatosensory-evoked potential (SSEP) monitoring is commonly used to detect changes in nerve conduction and prevent impending nerve injury. We present a case series of two patients who had SSEP monitoring for their surgical craniotomy procedure, and who, upon positioning supine with their head tilte...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Anesthesia and analgesia 2009-09, Vol.109 (3), p.817-821
Hauptverfasser: Anastasian, Zirka H., Ramnath, Brian, Komotar, Ricardo J., Bruce, Jeffrey N., Sisti, Michael B., Gallo, Edward J., Emerson, Ronald G., Heyer, Eric J.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Somatosensory-evoked potential (SSEP) monitoring is commonly used to detect changes in nerve conduction and prevent impending nerve injury. We present a case series of two patients who had SSEP monitoring for their surgical craniotomy procedure, and who, upon positioning supine with their head tilted 30°–45°, developed unilateral upper extremity SSEP changes. These SSEP changes were reversed when the patients were repositioned. These cases indicate the clinical usefulness of monitoring SSEPs while positioning the patient and adjusting position accordingly to prevent injury.
ISSN:0003-2999
1526-7598
DOI:10.1213/ane.0b013e3181b086bd