In Vivo Dynamic Deformation of the Mitral Valve Annulus

Though mitral valve (MV) repair surgical procedures have increased in the United States [Gammie, J. S., et al. Ann. Thorac. Surg. 87(5):1431-1437, 2009; Nowicki, E. R., et al. Am. Heart J. 145(6):1058-1062, 2003], studies suggest that altering MV stress states may have an effect on tissue homeostasi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Annals of biomedical engineering 2009-09, Vol.37 (9), p.1757-1771
Hauptverfasser: Eckert, Chad E, Zubiate, Brett, Vergnat, Mathieu, Gorman, Joseph H. III, Gorman, Robert C, Sacks, Michael S
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Though mitral valve (MV) repair surgical procedures have increased in the United States [Gammie, J. S., et al. Ann. Thorac. Surg. 87(5):1431-1437, 2009; Nowicki, E. R., et al. Am. Heart J. 145(6):1058-1062, 2003], studies suggest that altering MV stress states may have an effect on tissue homeostasis, which could impact the long-term outcome [Accola, K. D., et al. Ann. Thorac. Surg. 79(4):1276-1283, 2005; Fasol, R., et al. Ann. Thorac. Surg. 77(6):1985-1988, 2004; Flameng, W., P. Herijgers, and K. Bogaerts. Circulation 107(12):1609-1613, 2003; Gillinov, A. M., et al. Ann. Thorac. Surg. 69(3):717-721, 2000]. Improved computational modeling that incorporates structural and geometrical data as well as cellular components has the potential to predict such changes; however, the absence of important boundary condition information limits current efforts. In this study, novel high definition in vivo annular kinematic data collected from surgically implanted sonocrystals in sheep was fit to a contiguous 3D spline based on quintic-order hermite shape functions with C² continuity. From the interpolated displacements, the annular axial strain and strain rate, bending, and twist along the entire annulus were calculated over the cardiac cycle. Axial strain was shown to be regionally and temporally variant with minimum and maximum values of -10 and 4%, respectively, observed. Similarly, regionally and temporally variant strain rate values, up to 100%/s contraction and 120%/s elongation, were observed. Both annular bend and twist data showed little deviation from unity with limited regional variations, indicating that most of the energy for deformation was associated with annular axial strain. The regionally and temporally variant strain/strain rate behavior of the annulus are related to the varied fibrous-muscle structure and contractile behavior of the annulus and surrounding ventricular structures, although specific details are still unavailable. With the high resolution shape and displacement information described in this work, high fidelity boundary conditions can be prescribed in future MV finite element models, leading to new insights into MV function and strategies for repair.
ISSN:0090-6964
1573-9686
1521-6047
DOI:10.1007/s10439-009-9749-3