Glucose Levels at the Site of Subcutaneous Insulin Administration and Their Relationship to Plasma Levels

OBJECTIVE: To examine insulin's effect on the tissue glucose concentration at the site of subcutaneous insulin administration. RESEARCH DESIGN AND METHODS: A CMA-60 microdialysis (MD) catheter and a 24-gauge microperfusion (MP) catheter were inserted into the subcutaneous adipose tissue of fast...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Diabetes care 2010-04, Vol.33 (4), p.833-838
Hauptverfasser: Lindpointner, Stefan, Korsatko, Stefan, Köhler, Gerd, Köhler, Hans, Schaller, Roland, Schaupp, Lukas, Ellmerer, Martin, Pieber, Thomas R, Regittnig, Werner
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:OBJECTIVE: To examine insulin's effect on the tissue glucose concentration at the site of subcutaneous insulin administration. RESEARCH DESIGN AND METHODS: A CMA-60 microdialysis (MD) catheter and a 24-gauge microperfusion (MP) catheter were inserted into the subcutaneous adipose tissue of fasting, healthy subjects (n = 5). Both catheters were perfused with regular human insulin (100 units/ml) over a 6-h period and used for glucose sampling and simultaneous administration of insulin at sequential rates of 0.33, 0.66, and 1.00 units/h (each rate was used for 2 h). Before and after the insulin delivery period, both catheters were perfused with an insulin-free solution (5% mannitol) for 2 h and used for glucose sampling only. Blood plasma glucose was clamped at euglycemic levels during insulin delivery. RESULTS: Start of insulin delivery with MD and MP catheters resulted in a decline of the tissue glucose concentration and the tissue-to-plasma glucose ratio (TPR) for ~60 min (P < 0.05). However, during the rest of the 6-h period of variable insulin delivery, tissue glucose concentration paralleled the plasma glucose concentration, and the TPR for MD and MP catheters remained unchanged at 83.2 ± 3.1 and 77.1 ± 4.8%, respectively. After subsequent switch to insulin-free perfusate, tissue glucose concentration and TPR increased slowly and reattained preinsulin delivery levels by the end of the experiments. CONCLUSIONS: The results show the attainment of a stable TPR value at the site of insulin administration, thus indicating that insulin delivery and glucose sensing may be performed simultaneously at the same adipose tissue site.
ISSN:0149-5992
1935-5548
1935-5548
DOI:10.2337/dc09-1531