Effects of graded pulsatile pressure on the reflex vasomotor responses elicited by changes of mean pressure in the perfused carotid sinus-aortic arch regions of the dog
1. In the anaesthetized dog, the carotid sinuses and aortic arch were isolated from the circulation and separately perfused with blood by a method which enabled the mean pressure, pulse pressure and pulse frequency to be varied independently in each vasosensory area. The systemic circulation was per...
Gespeichert in:
Veröffentlicht in: | The Journal of physiology 1971-04, Vol.214 (1), p.51-64 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | 1. In the anaesthetized dog, the carotid sinuses and aortic arch were isolated from the circulation and separately perfused
with blood by a method which enabled the mean pressure, pulse pressure and pulse frequency to be varied independently in each
vasosensory area. The systemic circulation was perfused at constant blood flow by means of a pump and the systemic venous
blood was oxygenated by an extracorporeal isolated pump-perfused donor lung preparation.
2. We have confirmed our previous observations that under steadystate conditions the vasomotor responses elicited reflexly
by changes in mean carotid sinus pressure are modified by alterations in carotid sinus pulse pressure, whereas those evoked
by changes of mean aortic arch pressure are only weakly affected by modifications of aortic pulse pressure.
3. When the carotid sinus and aortic arch regions are perfused in combination at constant pulse frequency (110 c/min), the
relationship between mean carotid sinus-aortic arch pressure and systemic arterial perfusion pressure is dependent on the
size of the pulse pressure.
4. Increasing the pulse pressure alters the curve relating the mean carotid sinus-aortic arch pressure to systemic arterial
perfusion pressure in such a way that the perfusion pressure is lower at a given carotid sinus-aortic arch pressure within
the range 80-150 mm Hg. The larger the pulse pressure, up to about 60 mm Hg, the greater the fall in systemic arterial perfusion
pressure. Above a mean carotid sinus-aortic arch pressure of about 150 mm Hg, alterations of pulse pressure have little effect.
5. There is a family of curves representing the relation between mean carotid sinus-aortic arch pressure and systemic vascular
resistance, depending on the pulse pressure. |
---|---|
ISSN: | 0022-3751 1469-7793 |
DOI: | 10.1113/jphysiol.1971.sp009418 |