Oxygen consumption and neonatal sleep states
1. In thirty full-term infants in the first week of life, nursed in a constant volume, closed-circuit metabolism chamber in a neutral thermal environment (31·5-33·5 °C), measurements were made of oxygen consumption ( VÌ O 2 ) during periods of rapid eye movement (REM) sleep and non-rapid eye mov...
Gespeichert in:
Veröffentlicht in: | The Journal of physiology 1978-05, Vol.278 (1), p.435-440 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | 1. In thirty full-term infants in the first week of life, nursed in a constant volume, closed-circuit metabolism chamber in
a neutral thermal environment (31·5-33·5 °C), measurements were made of oxygen consumption ( VÌ O 2 ) during periods of rapid eye movement (REM) sleep and non-rapid eye movement (NREM) sleep.
2. The mean VÌ O 2 during REM sleep was 5·97 ml. kg -1 . min -1 . In NREM sleep the mean VÌ O 2 was 5·72 ml. kg -1 . min -1 . This difference was significant (paired t test P < 0·05).
3. When the direction of sleep state change was taken into account the difference in VÌ O 2 between the two states was much less when REM sleep preceded NREM than when the change was in the opposite direction. In
nineteen infants in whom the change was from REM to NREM the difference in VÌ O 2 (6·18 and 6·03 ml. kg -1 . min -1 ) was not significant ( P > 0·05). The mean difference when the sleep state change was from NREM to REM was significant ( P < 0·01), the values being 5·54 and 5·81 ml. kg -1 . min -1 respectively.
4. In the NREM state, a gradual diminution of VÌ O 2 with time was consistently found. This was not the case in REM sleep.
5. In twelve infants studied in a cool environment (29 ± 0·5 °C) VÌ O 2 during REM sleep was 7·77, and during NREM sleep it was 6·58 ml. kg -1 . min -1 , ( P < 0·001). Thus even the maximum difference found in a neutral thermal environment of 6·6% was significantly increased to
14·9% ( P < 0·01) with mild thermal stress.
6. No consistent changes in VÌ O 2 with time were found in either REM or NREM sleep in twelve infants studied in a cool environment, in contrast to the findings
in thermal neutrality |
---|---|