Effectiveness of positron emission tomography for the detection of melanoma metastases

The purpose of this study was to determine the sensitivity, specificity, and clinical utility of 18F 2-fluoro-2-deoxy-D-glucose (FDG) total-body positron emission tomography (PET) scanning for the detection of metastases in patients with malignant melanoma. Recent preliminary reports suggest that PE...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Annals of surgery 1998-05, Vol.227 (5), p.764-771
Hauptverfasser: Holder, Jr, W D, White, Jr, R L, Zuger, J H, Easton, Jr, E J, Greene, F L
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The purpose of this study was to determine the sensitivity, specificity, and clinical utility of 18F 2-fluoro-2-deoxy-D-glucose (FDG) total-body positron emission tomography (PET) scanning for the detection of metastases in patients with malignant melanoma. Recent preliminary reports suggest that PET using FDG may be more sensitive and specific for detection of metastatic melanoma than standard radiologic imaging studies using computed tomography (CT). PET technology is showing utility in the detection of metastatic tumors from multiple primary sites including breast, lung, lymphoma, and melanoma. However, little information is available concerning the general utility, sensitivity, and specificity of PET scanning of patients with metastatic melanoma. One hundred three PET scans done on 76 nonrandomized patients having AJCC stage II to IV melanoma were prospectively evaluated. Patients were derived from two groups. Group 1 (63 patients) had PET, CT (chest and abdomen), and magnetic resonance imaging (MRI; brain) scans as a part of staging requirements for immunotherapy protocols. Group 2 (13 nonprotocol patients) had PET, CT, and MRI scans as in group 1, but for clinical evaluation only. PET scans were done using 12 to 20 mCi of FDG given intravenously. Results of PET scans were compared to CT scans and biopsy or cytology results. PET scanning for the detection of melanoma metastases had a sensitivity of 94.2% and a specificity of 83.3% compared to 55.3% and 84.4%, respectively, for CT scanning. Factors that produced false-positive PET scans were papillary carcinoma of the thyroid (1), bronchogenic carcinoma (1), inflamed epidermal cyst (1), Warthin's tumor of the parotid gland (1), surgical wound inflammation (2), leiomyoma of the uterus (1), suture granuloma (1), and endometriosis (1). The four false-negative scans were thought to be due to smaller (
ISSN:0003-4932
1528-1140
DOI:10.1097/00000658-199805000-00017