Novel Approach to Maintaining Patency of an Abdominal Aortic Graft Required for Emergent Cannulation

A 32-year-old woman with end-stage heart failure and complex anatomy underwent placement of a vascular graft to facilitate arterial cannulation during planned heart transplantation. The procedure involved anastomosis of a prosthetic graft to the abdominal aorta. The vascular graft was plugged with a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Annals of thoracic surgery short reports 2024-03, Vol.2 (1), p.121-124
Hauptverfasser: Johnson, Blaine, Onsager, David, Tung, Avery, Zarifa, Rolla, Landeras, Luis, Pinney, Sean, Milner, Ross, Jeevanandam, Valluvan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A 32-year-old woman with end-stage heart failure and complex anatomy underwent placement of a vascular graft to facilitate arterial cannulation during planned heart transplantation. The procedure involved anastomosis of a prosthetic graft to the abdominal aorta. The vascular graft was plugged with a silicone Foley catheter containing a stopper to maintain patency. This novel approach was safe when performed by a multidisciplinary surgical team experienced in vascular and adult congenital cardiac surgical procedures.
ISSN:2772-9931
2772-9931
DOI:10.1016/j.atssr.2023.08.004