High-intensity Focused Ultrasound-A New Choice to Conduct Pulmonary Artery Denervation

This research aimed to explore whether high-intensity focused ultrasound (HIFU) could conduct pulmonary artery denervation (PADN). HIFU was performed in pulmonary arteries of 6 normotensive rabbits at dose of 250W, 6 times for each rabbit, and an additional 6 rabbits served as controls. Then ATEPH w...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of cardiovascular translational research 2024-12, Vol.17 (6), p.1353-1364
Hauptverfasser: Xie, Yonghui, Yao, Taoyue, Zhu, Xiaogang, Yang, Fan, Fan, Haoqin, Cao, Shirui, Chen, Huaiyang, Liao, Manzhen, Xia, Yuanxi, Liu, Jinqiao, Xiao, Zhenghui, Yang, Zhou, Xiao, Yunbin
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This research aimed to explore whether high-intensity focused ultrasound (HIFU) could conduct pulmonary artery denervation (PADN). HIFU was performed in pulmonary arteries of 6 normotensive rabbits at dose of 250W, 6 times for each rabbit, and an additional 6 rabbits served as controls. Then ATEPH was induced in both groups by intravenous infusion of autogeneic thrombus. Hemodynamics and ultrasonography parameters were measured by right heart catheter and echocardiography pre- and post-establishment of ATEPH models in both groups. Histological analysis and immunohistochemistry of tyrosine hydroxylase (TH) were also performed. After PADN procedures, 5 rabbits were successfully conducted PADN, of which ablation zone was also observed in right auricle or right lung in 4 rabbits. Ablation zone was detected only in right lung in 1 rabbit. Compared with control group, milder right heart hemodynamic changes were found in PADN group, accompanied by improved ultrasound parameters in PADN group. HIFU can acutly damage SNs around pulmonary artery successfully, which may be a new choice to conduct PADN. However, the accuracy of HIFU with PADN needs to be improved. Graphical Abstract
ISSN:1937-5387
1937-5395
1937-5395
DOI:10.1007/s12265-024-10531-9