Magnum metal-on-metal uncemented total hip replacement: 8- to 18-year outcomes of 211 cases

Background Reports of adverse reactions to metal debris contributed in part to a decline in use of large-bearing metal-on-metal total hip devices. We hypothesize an optimal trunnion design may reduce risk of this failure mode in large-bearing total hip arthroplasty systems. The purpose of this study...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Musculoskeletal surgery 2024-12, Vol.108 (4), p.449-457
Hauptverfasser: Gaillard-Campbell, D., Gross, T.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background Reports of adverse reactions to metal debris contributed in part to a decline in use of large-bearing metal-on-metal total hip devices. We hypothesize an optimal trunnion design may reduce risk of this failure mode in large-bearing total hip arthroplasty systems. The purpose of this study is to report mid- to long-term outcomes for a single-surgeon series of 211 total hip arthroplasties using the large-bearing Biomet Magnum metal-on-metal system. Materials and methods Between December 2004 and January 2016, the primary surgeon performed 211 uncemented Magnum total hip arthroplasties in 181 patients. The average length of follow-up was 10.1 ± 3.5 years (range 8–18 years). Results Using failure of any component as the endpoint, the overall survivorship rate was 98.1% at 10 years and 97.4% at 18 years. These eight failures (3.8% of cohort) included one case of adverse wear-related failure (0.5%), two cases of acetabular ingrowth failure (0.9%), three cases of trunnion corrosion (1.4%), one failure of late infection (0.5%), and one inappropriate revision of components for trochanteric nonunion without instability (0.5%). Excluding failed cases, all components were radiographically stable with no radiolucencies. Except for the one wear failure, ion testing revealed that 97.2% of cases were within optimal whole blood metal ion levels with the remaining ion test results within acceptable levels. Conclusions With the uncemented Magnum metal-on-metal total hip, we achieved 97.4% 18-year implant survivorship, exceeding the NICE criteria and registry benchmarks for implant survivorship. We observed a trunnion corrosion rate of 1.4% and no cases of instability. The single case of adverse wear-related failure was caused by acetabular component malposition.
ISSN:2035-5106
2035-5114
2035-5114
DOI:10.1007/s12306-024-00831-3