Characterization and enhanced carbon dioxide sensing performance of spin-coated Na- and Li-doped and Co-doped cobalt oxide thin films

Recognizing the substantial effects of carbon dioxide on human health and the environment, monitoring CO 2 levels has become increasingly vital. Owing to energy constraints and the widespread application of CO 2 gas sensors, it is important to design cost-effective, more efficient, and faster respon...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:RSC advances 2024-11, Vol.14 (49), p.36852-36867
Hauptverfasser: Saad, Rana, Abdelkarem, Khaled, El Sayed, Adel M., Shaban, Mohamed, Ahmed, Inas A., Tammam, M. T., Hamdy, Hany
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Recognizing the substantial effects of carbon dioxide on human health and the environment, monitoring CO 2 levels has become increasingly vital. Owing to energy constraints and the widespread application of CO 2 gas sensors, it is important to design cost-effective, more efficient, and faster response CO 2 gas sensors that operate at room temperature and involve a low-cost technique. This study aims to develop a cost-effective and efficient CO 2 gas detector that functions at room temperature and uses less power than traditional high-temperature CO 2 sensors. In this study, we achieved this by employing innovative Co 3 O 4 thin films with optimized spinel-structured p-type semiconductors through spin-coating, facilitated by Li and Na doping as well as Li/Na codoping. Doping with 3% Li/Na reduced the crystallite size from 92.4 to 8.03 nm and increased the band gap from 3.31 to 3.69 eV. At room temperature (30 °C), the sensor response improved significantly, increasing from 50% to 345.01% for 3% Li-Co 3 O 4 upon the addition of 3% Na at a concentration of 9990 ppm. This performance surpasses that of most metal-oxide-based CO 2 sensors reported in the literature. Additionally, this optimized sensor demonstrated a very short response time of 18.8 s and a recovery time of 16.4 s at a CO 2 concentration of 9990 ppm diluted with air. It outperformed other films in terms of sensitivity, stability, response and recovery times, and performance across a wide range of relative humidity levels (43–90%). The sensor exhibited superior selectivity for CO 2 than for N 2 , H 2 , and NH 3 . Overall, the 3% Li, Na-Co 3 O 4 sensor is well-suited for climate change mitigation and industrial applications.
ISSN:2046-2069
2046-2069
DOI:10.1039/d4ra06847e