Non-linear relationship between O2 uptake and power output at high intensities of exercise in humans
1. A slow component to pulmonary oxygen uptake (VO2) is reported during prolonged high power exercise performed at constant power output at, or above, approximately 60% of the maximal oxygen uptake. The magnitude of the slow component is reported to be associated with the intensity of exercise and t...
Gespeichert in:
Veröffentlicht in: | The Journal of physiology 1995-10, Vol.488 (Pt 1), p.211-217 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | 1. A slow component to pulmonary oxygen uptake (VO2) is reported during prolonged high power exercise performed at constant
power output at, or above, approximately 60% of the maximal oxygen uptake. The magnitude of the slow component is reported
to be associated with the intensity of exercise and to be largely accounted for by an increased VO2 across the exercising
legs. 2. On the assumption that the control mechanism responsible for the increased VO2 is intensity dependent we hypothesized
that it should also be apparent in multi-stage incremental exercise tests with the result that the VO2-power output relationship
would be curvilinear. 3. We further hypothesized that the change in the VO2-power output relationship could be related to
the hierarchical recruitment of different muscle fibre types with a lower mechanical efficiency. 4. Six subjects each performed
five incremental exercise tests, at pedalling rates of 40, 60, 80, 100 and 120 rev min-1, over which range we expected to
vary the proportional contribution of different fibre types to the power output. Pulmonary VO2 was determined continuously
and arterialized capillary blood was sampled and analysed for blood lactate concentration ([lactate]b). 5. Below the level
at which a sustained increase in [lactate]b was observed pulmonary VO2 showed a linear relationship with power output; at
high power outputs, however, there was an additional increase in VO2 above that expected from the extrapolation of that linear
relationship, leading to a positive curvilinear VO2-power output relationship. 6. No systematic effect on the magnitude or
onset of the 'extra' VO2 was found in relation to pedalling rate, which suggests that it is not related to the pattern of
motor unit recruitment in any simple way. |
---|---|