Tissue oedema following pulsed field ablation recognized during a concomitant left atrial appendage closure procedure: a case report
Abstract Background In patients with non-valvular atrial fibrillation (AF), at high stroke risk, and who are ineligible for long-term oral anticoagulation, the left atrial appendage closure (LAAC) could be an alternative to anticoagulation. Pulsed field ablation (PFA) is a new non-thermal method for...
Gespeichert in:
Veröffentlicht in: | European heart journal : case reports 2024-09, Vol.8 (9), p.ytae495 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Abstract
Background
In patients with non-valvular atrial fibrillation (AF), at high stroke risk, and who are ineligible for long-term oral anticoagulation, the left atrial appendage closure (LAAC) could be an alternative to anticoagulation. Pulsed field ablation (PFA) is a new non-thermal method for cardiac ablation modality based on high-voltage electrical energy for irreversible electroporation. We first report a case of a concomitant PFA pulmonary vein isolation (PVI) and LAAC.
Case summary
A 74-year-old female patient was referred to our department for PVI for persistent AF (CHA2DS2-VASc score 5). A concomitant percutaneous LAAC was proposed because of a history of previous cerebellar transient ischaemic attack despite continuous oral anticoagulation therapy. Pulmonary vein isolation was achieved with a pentaspline PFA catheter, and LAAC was performed with a WATCHMAN FLX™ device (Boston Scientific, Plymouth, MN, USA). After PVI, a swelling of the left atrial ridge was observed, yet a 27 mm LAAC device was successfully implanted. The follow-up transesophageal echo (TEE) after 6 weeks showed complete resolution of the oedema, no device-related thrombus, but a slight proximal tilting of the LAAC device without leakage could be observed. The 6-month follow-up demonstrated a stable sinus rhythm, no stroke, or bleeding events were recorded.
Discussion
In this case of synchronous PFA-PVI procedure in AF and WATCHMAN FLX™ device implantation, the electroporation created an acute oedema at the ridge level which at the TEE follow-up after 6 weeks was resolved. This resulted in a slightly tilted WATCHMAN device position which was nevertheless stable and showed no leakage. |
---|---|