Pharmacokinetic-pharmacodynamic analysis of drug liking blockade by buprenorphine subcutaneous depot (CAM2038) in participants with opioid use disorder
Buprenorphine is used to treat opioid use disorder (OUD). Weekly and monthly subcutaneous long-acting buprenorphine injections (CAM2038) provide more stable buprenorphine plasma levels and reduce the treatment burden, misuse, and diversion associated with sublingual transmucosal buprenorphine formul...
Gespeichert in:
Veröffentlicht in: | Neuropsychopharmacology (New York, N.Y.) N.Y.), 2024-05, Vol.49 (6), p.1050-1057 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Buprenorphine is used to treat opioid use disorder (OUD). Weekly and monthly subcutaneous long-acting buprenorphine injections (CAM2038) provide more stable buprenorphine plasma levels and reduce the treatment burden, misuse, and diversion associated with sublingual transmucosal buprenorphine formulations. To characterize the pharmacokinetic/pharmacodynamic (PK/PD) relationship, a maximum inhibition (I
) model was developed relating CAM2038 buprenorphine plasma concentration to drug liking maximum effect (E
) visual analog scale (VAS; bipolar) score after intramuscular hydromorphone administration. Data included time-matched observations of buprenorphine plasma concentration and drug liking E
VAS score after hydromorphone 18 mg administration in 47 non-treatment-seeking adults with moderate to severe OUD in a phase 2 study. Analysis used non-linear mixed-effects modeling (NONMEM
). The final I
model adequately described the PK/PD relationship between buprenorphine plasma concentration and drug liking E
VAS score. Simulations showed drug liking was effectively blocked at low buprenorphine plasma concentrations (0.4 ng/mL) where the upper 95% confidence interval of the drug liking E
VAS score was below the pre-defined 11-point complete blockade threshold. The buprenorphine plasma concentration required to achieve 90% of the maximal effect (IC
) of drug liking was 0.675 ng/mL. Interindividual variability in responses to buprenorphine was observed; some participants experienced fluctuating responses, and a few did not achieve drug liking blockade even with higher buprenorphine plasma concentrations. This affirms the need to individualize treatment and titrate doses for optimal treatment outcomes. PK/PD models were also developed for desire to use VAS and Clinical Opiate Withdrawal Scale (COWS) scores, with results aligned to those for drug liking. |
---|---|
ISSN: | 0893-133X 1740-634X 1740-634X |
DOI: | 10.1038/s41386-023-01793-z |