The Femur-First Technique for Oxford Medial Unicompartmental Knee Arthroplasty

Unicompartmental knee arthroplasty (UKA) is a reliable procedure to treat medial compartment knee osteoarthritis (OA). The reported survivorship of UKA has varied in the literature . In part, the higher failure rates of UKA seen in registries could be related to the caseload and experience of the re...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:JBJS essential surgical techniques 2024-04, Vol.14 (2)
Hauptverfasser: Alarcon Perico, Diego, Lee, Sheng-Hsun, Labott, Josh R, Guarin Perez, Sergio F, Sierra, Rafael J
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Unicompartmental knee arthroplasty (UKA) is a reliable procedure to treat medial compartment knee osteoarthritis (OA). The reported survivorship of UKA has varied in the literature . In part, the higher failure rates of UKA seen in registries could be related to the caseload and experience of the reporting surgeon . The introduction of techniques that make procedures more reliable, especially in the hands of inexperienced surgeons, can decrease the rate of failure. With the Oxford UKA implant (Zimmer Biomet), the recommended surgical technique involves cutting the tibia first, followed by the femoral preparation. However, a technique that allows for preparation of the femur first, as well as the use of the femoral component as a reference for the tibial cut, may reduce the common technical errors seen with the procedure. We have utilized the femur-first technique in cases of medial Oxford UKA. The femur-first method outlined in the present article does not require any unique instruments beyond what is supplied by the manufacturer. Before beginning, the femoral positional guide needs to be decoupled from its base. To start, the intramedullary guide is introduced approximately 1 cm anterior and medial to the intercondylar notch. Once the femoral osteophytes are removed, the surgeon identifies the center of the femoral condyle and marks it. The posterior tibial cartilage is then removed with a saw to facilitate the placement of the appropriately sized femoral spherical guide. The size of the femoral component is determined by selecting the implant that aligns best with the width of the femoral condyle. The femoral drill guide is detached from its base because there is not enough space for the base, as the tibia has not yet been resected. The decoupled femoral guide is connected to the intramedullary rod, allowing the precise positioning of the femoral component in approximately 10° of flexion relative to the femoral sagittal plane and drilling of the 2 peg holes. The posterior condylar resection guide is impacted into position, and the osteotomy of the posterior condyle is made. The distal femur is then milled with use of a number-0 spigot, and the femoral component trial is positioned into place. The femoral condyle is "resurfaced" with the femoral component, which restores joint obliquity and the natural height, a critical element of the femur-first technique. Following this, the 1-mm (size-dependent) spherical gauge is placed around the femoral component t
ISSN:2160-2204
2160-2204
DOI:10.2106/JBJS.ST.23.00059