A nasal airflow oscillation device targeting nasal congestion: a preliminary report
Purpose Upper respiratory tract complaints are common in the general population. A safe, non-pharmacologic treatment would be an attractive option for many patients either as an alternative to existing therapies, or as a complementary therapy. This study assessed the acceptability, safety and possib...
Gespeichert in:
Veröffentlicht in: | European archives of oto-rhino-laryngology 2024-05, Vol.281 (5), p.2743-2747 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose
Upper respiratory tract complaints are common in the general population. A safe, non-pharmacologic treatment would be an attractive option for many patients either as an alternative to existing therapies, or as a complementary therapy. This study assessed the acceptability, safety and possible efficacy of a nasal airflow oscillation device in a group of people suffering chronic nasal congestion.
Methods
Subjects with a known history of nasal congestion, but without fixed anatomical obstruction, participated in a prospective clinical study. Efficacy was assessed using peak nasal inspiratory flow (NPIF) and a 10-point visual analogue scale (VAS) administered before and after the oscillation device had been worn for twenty minutes.
Results
Twenty-one subjects (mean age 37 years; 43% female) were enrolled in the study. After treatment with the small nasal airflow oscillation device for twenty minutes, average NPIF increased significantly from 84.8 L/minute to 99.0 L/minute (
p
|
---|---|
ISSN: | 0937-4477 1434-4726 |
DOI: | 10.1007/s00405-024-08576-2 |