RobOCTNet: Robotics and Deep Learning for Referable Posterior Segment Pathology Detection in an Emergency Department Population

To evaluate the diagnostic performance of a robotically aligned optical coherence tomography (RAOCT) system coupled with a deep learning model in detecting referable posterior segment pathology in OCT images of emergency department patients. A deep learning model, RobOCTNet, was trained and internal...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Translational vision science & technology 2024-03, Vol.13 (3), p.12-12
Hauptverfasser: Song, Ailin, Lusk, Jay B, Roh, Kyung-Min, Hsu, S Tammy, Valikodath, Nita G, Lad, Eleonora M, Muir, Kelly W, Engelhard, Matthew M, Limkakeng, Alexander T, Izatt, Joseph A, McNabb, Ryan P, Kuo, Anthony N
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:To evaluate the diagnostic performance of a robotically aligned optical coherence tomography (RAOCT) system coupled with a deep learning model in detecting referable posterior segment pathology in OCT images of emergency department patients. A deep learning model, RobOCTNet, was trained and internally tested to classify OCT images as referable versus non-referable for ophthalmology consultation. For external testing, emergency department patients with signs or symptoms warranting evaluation of the posterior segment were imaged with RAOCT. RobOCTNet was used to classify the images. Model performance was evaluated against a reference standard based on clinical diagnosis and retina specialist OCT review. We included 90,250 OCT images for training and 1489 images for internal testing. RobOCTNet achieved an area under the curve (AUC) of 1.00 (95% confidence interval [CI], 0.99-1.00) for detection of referable posterior segment pathology in the internal test set. For external testing, RAOCT was used to image 72 eyes of 38 emergency department patients. In this set, RobOCTNet had an AUC of 0.91 (95% CI, 0.82-0.97), a sensitivity of 95% (95% CI, 87%-100%), and a specificity of 76% (95% CI, 62%-91%). The model's performance was comparable to two human experts' performance. A robotically aligned OCT coupled with a deep learning model demonstrated high diagnostic performance in detecting referable posterior segment pathology in a cohort of emergency department patients. Robotically aligned OCT coupled with a deep learning model may have the potential to improve emergency department patient triage for ophthalmology referral.
ISSN:2164-2591
2164-2591
DOI:10.1167/tvst.13.3.12