Hybrid surgery of vertebral artery transposition combined with scallop and fenestration technique for the repair of type B aortic dissection patient with isolated left vertebral artery: A case report

Acute type B aortic dissection (ABAD) is a fatal cardiovascular disease with high morbidity and mortality. Isolated left vertebral artery (ILVA) is a rare aortic arch mutation originating from the aortic arch. The simultaneous occurrence of both increases the complexity and difficulty of thoracic en...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Medicine (Baltimore) 2024-03, Vol.103 (10), p.e37410-e37410
Hauptverfasser: Ge, Shuxiong, Xu, Zhongyou, Yan, Jinlin
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Acute type B aortic dissection (ABAD) is a fatal cardiovascular disease with high morbidity and mortality. Isolated left vertebral artery (ILVA) is a rare aortic arch mutation originating from the aortic arch. The simultaneous occurrence of both increases the complexity and difficulty of thoracic endovascular aortic repair. However, there have been few reports on the recommendation of thoracic endovascular aortic repair treatment strategies for aortic dissection patients concomitant ILVA with insufficient landing zone. Here, we report a case of ABAD combined with ILVA treated with hybrid surgery of left vertebral artery transposition alliance with Scallop and in vivo fenestration endograft. A 38-year-old middle-aged man was transferred to our vascular department with persistent pain in his lower abdomen for 8 hours. Preoperative computed tomography angiogram of the thoracic and abdominal aorta diagnosed with ABAD accompanied with ILVA. Hybrid surgery of left vertebral artery transposition alliance with Scallop and in situ fenestration endograft for revascularization of ILVA, left subclavian artery, and left common carotid artery. The hybridization operation was successfully completed. There were no complications of cerebral and spinal cord ischemia after operation. Computed tomography angiogram examination indicated no internal leakage existed in the stent and patency of the arch vessels and the transposed left vertebral artery follow-up 3 months after surgery. This study gave us experience in the treatment of aortic dissection with left vertebral artery variation and suggested that left vertebral artery transposition combined with scallop and in vivo fenestration stent is safe and effective.
ISSN:0025-7974
1536-5964
DOI:10.1097/MD.0000000000037410