Two is better than one: longitudinal detection and volumetric evaluation of brain metastases after Stereotactic Radiosurgery with a deep learning pipeline
Purpose Close MRI surveillance of patients with brain metastases following Stereotactic Radiosurgery (SRS) treatment is essential for assessing treatment response and the current disease status in the brain. This follow-up necessitates the comparison of target lesion sizes in pre- (prior) and post-S...
Gespeichert in:
Veröffentlicht in: | Journal of neuro-oncology 2024-02, Vol.166 (3), p.547-555 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose
Close MRI surveillance of patients with brain metastases following Stereotactic Radiosurgery (SRS) treatment is essential for assessing treatment response and the current disease status in the brain. This follow-up necessitates the comparison of target lesion sizes in pre- (prior) and post-SRS treatment (current) T1W-Gad MRI scans. Our aim was to evaluate SimU-Net, a novel deep-learning model for the detection and volumetric analysis of brain metastases and their temporal changes in paired prior and current scans.
Methods
SimU-Net is a simultaneous multi-channel 3D U-Net model trained on pairs of registered prior and current scans of a patient. We evaluated its performance on 271 pairs of T1W-Gad MRI scans from 226 patients who underwent SRS. An expert oncological neurosurgeon manually delineated 1,889 brain metastases in all the MRI scans (1,368 with diameters > 5 mm, 834 > 10 mm). The SimU-Net model was trained/validated on 205 pairs from 169 patients (1,360 metastases) and tested on 66 pairs from 57 patients (529 metastases). The results were then compared to the ground truth delineations.
Results
SimU-Net yielded a mean (std) detection precision and recall of 1.00±0.00 and 0.99±0.06 for metastases > 10 mm, 0.90±0.22 and 0.97±0.12 for metastases > 5 mm of, and 0.76±0.27 and 0.94±0.16 for metastases of all sizes. It improves lesion detection precision by 8% for all metastases sizes and by 12.5% for metastases |
---|---|
ISSN: | 0167-594X 1573-7373 |
DOI: | 10.1007/s11060-024-04580-y |