Study Design Retrospective analysis of prospectively collected data. Objectives Our goal was to assess radiographic characteristics associated with agreement and disagreement in treatment recommendation in thoracolumbar (TL) burst fractures. Methods A panel of 22 AO Spine Knowledge Forum Trauma expe...
Gespeichert in:
Veröffentlicht in: | Global spine journal 2024-02, Vol.14 (1_suppl), p.25S-31S |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Study Design
Retrospective analysis of prospectively collected data.
Objectives
Our goal was to assess radiographic characteristics associated with agreement and disagreement in treatment recommendation in thoracolumbar (TL) burst fractures.
Methods
A panel of 22 AO Spine Knowledge Forum Trauma experts reviewed 183 cases and were asked to: (1) classify the fracture; (2) assess degree of certainty of PLC disruption; (3) assess degree of comminution; and (4) make a treatment recommendation. Equipoise threshold used was 77% (77:23 distribution of uncertainty or 17 vs 5 experts). Two groups were created: consensus vs equipoise.
Results
Of the 183 cases reviewed, the experts reached full consensus in only 8 cases (4.4%). Eighty-one cases (44.3%) were included in the agreement group and 102 cases (55.7%) in the equipoise group. A3/A4 fractures were more common in the equipoise group (92.0% vs 83.7%, P < .001). The agreement group had higher degree of certainty of PLC disruption [35.8% (SD 34.2) vs 27.6 (SD 27.3), P < .001] and more common use of the M1 modifier (44.3% vs 38.3%, P < .001). Overall, the degree of comminution was slightly higher in the equipoise group [47.8 (SD 20.5) vs 45.7 (SD 23.4), P < .001].
Conclusions
The agreement group had a higher degree of certainty of PLC injury and more common use of M1 modifier (more type B fractures). The equipoise group had more A3/A4 type fractures. Future studies are required to identify the role of comminution in decision making as degree of comminution was slightly higher in the equipoise group. |
---|---|