Night-to-night reliability and agreement of obstructive sleep apnea pathophysiologic mechanisms estimated with phenotyping using polysomnography in cognitively normal elderly participants
Abstract Study Objectives Phenotyping using polysomnography (PUP) is an algorithmic method to quantify physiologic mechanisms underlying obstructive sleep apnea (OSA): loop gain (LG1), arousal threshold (ArTH), and upper airway collapsibility (Vpassive) and muscular compensation (Vcomp). The consecu...
Gespeichert in:
Veröffentlicht in: | Sleep (New York, N.Y.) N.Y.), 2023-08, Vol.46 (8), p.1 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Abstract
Study Objectives
Phenotyping using polysomnography (PUP) is an algorithmic method to quantify physiologic mechanisms underlying obstructive sleep apnea (OSA): loop gain (LG1), arousal threshold (ArTH), and upper airway collapsibility (Vpassive) and muscular compensation (Vcomp). The consecutive-night test–retest reliability and agreement of PUP-derived estimates are unknown. From a cohort of elderly (age ≥55 years), largely non-sleepy, community-dwelling volunteers who underwent in-lab polysomnography (PSG) on 2 consecutive nights, we determined the test–retest reliability and agreement of PUP-estimated physiologic factors.
Methods
Participants who had an apnea–hypopnea index (AHI3A) of at least 15 events per hour on the first night were included. PUP analyses were performed on each of the two PSGs from each participant. Physiologic factor estimates were derived from NREM sleep and compared across nights using intraclass correlation coefficients for reliability and smallest real differences (SRD) for agreement.
Results
Two PSGs from each of 43 participants (86 total) were analyzed. A first-night effect was evident with increased sleep time and stability and decreased OSA severity on the second night. LG1, ArTH, and Vpassive demonstrated good reliability (ICC > 0.80). Vcomp had modest reliability (ICC = 0.67). For all physiologic factors, SRD values were approximately 20% or more of the observed ranges, suggesting limited agreement of longitudinal measurements for a given individual.
Conclusions
For NREM sleep in cognitively normal elderly individuals with OSA, PUP-estimated LG1, ArTH, and Vpassive demonstrated consistent relative ranking of individuals (good reliability) on short-term repeat measurement. For all physiologic factors, longitudinal measurements demonstrated substantial intraindividual variability across nights (limited agreement).
Graphical abstract
Graphical Abstract |
---|---|
ISSN: | 0161-8105 1550-9109 1550-9109 |
DOI: | 10.1093/sleep/zsad058 |