Adsorptive stripping voltammetric sensor based on Cd zeolitic imidazole framework-67 for electrochemical detection of sarin simulant
A selective and reliable modified glassy carbon sensor, based on a 1.0% Cd zeolitic imidazole framework-67 modified glassy carbon sensor (GCS 2 ), has been developed for ultrasensitive detection of dimethyl methyl phosphonate (DMMP) in human biological fluid. The synthesis of porous nanoparticles of...
Gespeichert in:
Veröffentlicht in: | Mikrochimica acta (1966) 2024-02, Vol.191 (2), p.80-80, Article 80 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A selective and reliable modified glassy carbon sensor, based on a 1.0% Cd zeolitic imidazole framework-67 modified glassy carbon sensor (GCS
2
), has been developed for ultrasensitive detection of dimethyl methyl phosphonate (DMMP) in human biological fluid. The synthesis of porous nanoparticles of Cd zeolitic imidazole framework-67 (Cd ZIF-67) was carried out via the hydrothermal method. The resulting Cd ZIF-67 powder emerges with good crystallinity, a rhombic dodecahedral morphology with particle size in the range 300 ~ 500 nm, and a specific surface area of 1780 m
2
·g
−1
. Furthermore, the fabricated sensor exhibited superior performance in the detection of DMMP with two linearity ranges of 0.02–2.0 nM and 2.0–9.0 nM and a limit of detection (LOD) of 0.06 pM. The fabricated sensor exhibited good reliability, long-term stability, and repeatability, which are favourable attributes for electroanalytical detection. In addition, the fabricated sensor displayed superior performance without significant interference during the assay of DMMP in a biological fluid (human serum sample) within two linearity ranges of 0.1–1.0 nM and 1.0–6.0 nM and a LOD of 0.03 nM.
Graphical Abstract |
---|---|
ISSN: | 0026-3672 1436-5073 |
DOI: | 10.1007/s00604-023-06112-3 |