Significant Reduction in External Ventricular Drain-Related Infections After Introducing a Novel Bundle Protocol: A Before and After Trial

External ventricular drain (EVD)-related infection (ERI) is a serious complication in neurosurgical patients. The estimated ERI rates range from 5 to 20 cases per 1,000 EVD catheter days. The pathophysiology of ERI is similar to central line-associated bloodstream infections (CLABSIs) stemming from...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of Korean medical science 2023-12, Vol.38 (50), p.e386-e386
Hauptverfasser: Choo, Yoon-Hee, Shim, Youngbo, Kim, Hyeseon, Goh, Hye Yeon, Kim, Su Jung, Kim, Eun Jin, Kang, Chang Kyung, Ha, Eun Jin
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:External ventricular drain (EVD)-related infection (ERI) is a serious complication in neurosurgical patients. The estimated ERI rates range from 5 to 20 cases per 1,000 EVD catheter days. The pathophysiology of ERI is similar to central line-associated bloodstream infections (CLABSIs) stemming from skin-derived bacterial colonization. The use of bundle management can reduce CLABSI rates. Due to the pathogenic similarities between infections related to the two devices, we developed and evaluated the effectiveness of an ERI-bundle protocol based on CLABSI bundles. From November 2016 to November 2021, we conducted a study to evaluate the effectiveness of an ERI-bundle protocol. This study adopted a before-and-after trial, comparing the ERI rates for the 2 years before and 3 years after the introduction of the newly developed ERI-bundle protocol. We also analyzed the contributing factors to ERI using logistic regression analysis. A total of 183 patients with 2,381 days of catheter use were analyzed. The ERI rate decreased significantly after the ERI-bundle protocol from 16.7% (14 of 84; 14.35 per 1,000 catheter days) to 4.0% (4 of 99; 3.21 per 1,000 catheter days) ( = 0.004). Introduction of the ERI-bundle protocol was very effective in reducing ERI.
ISSN:1011-8934
1598-6357
DOI:10.3346/jkms.2023.38.e386