Evaluating Receptor-Specific Fresh Specimen Staining for Tumor Margin Detection in Clinical Breast Specimens

Purpose Reliable and rapid identification of tumor in the margins of breast specimens during breast-conserving surgery to reduce repeat surgery rates is an active area of investigation. Dual-stain difference imaging (DDSI) is one of many approaches under evaluation for this application. This techniq...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Molecular imaging and biology 2023-10, Vol.25 (5), p.911-922
Hauptverfasser: Byrd, Brook K., Wells, Wendy A., Strawbridge, Rendall R., Barth, Connor W., Samkoe, Kimberley S., Gibbs, Summer L., Davis, Scott C.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Purpose Reliable and rapid identification of tumor in the margins of breast specimens during breast-conserving surgery to reduce repeat surgery rates is an active area of investigation. Dual-stain difference imaging (DDSI) is one of many approaches under evaluation for this application. This technique aims to topically apply fluorescent stain pairs (one targeted to a receptor-of-interest and the other a spectrally distinct isotype), image both stains, and compute a normalized difference image between the two channels. Prior evaluation and optimization in a variety of preclinical models produced encouraging diagnostic performance. Herein, we report on a pilot clinical study which evaluated HER2-targeted DDSI on 11 human breast specimens. Procedures Gross sections from 11 freshly excised mastectomy specimens were processed using a HER2-receptor-targeted DDSI protocol shortly after resection. After staining with the dual-probe protocol, specimens were imaged on a fluorescence scanner, followed by tissue fixation for hematoxylin and eosin and anti-HER2 immunohistochemical staining. Receiver operator characteristic curves and area under the curve (AUC) analysis were used to assess diagnostic performance of the resulting images. Performance values were also compared to expression level determined from IHC staining. Results Eight of the 11 specimens presented with distinguishable invasive ductal carcinoma and/or were not affected by an imaging artifact. In these specimens, the DDSI technique provided an AUC = 0.90 ± 0.07 for tumor-to-adipose tissue and 0.81 ± 0.15 for tumor-to-glandular tissue, which was significantly higher than AUC values recovered from images of the targeted probe alone. DDSI values and diagnostic performance did not correlate with HER2 expression level, and tumors with low HER2 expression often produced high AUC, suggesting that even the low expression levels were enough to help distinguish tumor. Conclusions The results from this preliminary study of rapid receptor-specific staining in human specimens were consistent with prior preclinical results and demonstrated promising diagnostic potential.
ISSN:1536-1632
1860-2002
DOI:10.1007/s11307-022-01771-9