A Case of Postthoracic Endovascular Aortic Repair Stent-Graft Infection Caused by Campylobacter insulaenigrae

An 81-year-old Japanese man who had distal aortic arch dilatation at age 77 had thoracic endovascular aortic surgery. The patient developed a fever and was taken to the hospital. Reduced diffusion in the descending aortic wall along the stent graft was discovered using whole-body diffusion-weighted...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Annals of Vascular Diseases 2023/09/25, Vol.16(3), pp.230-233
Hauptverfasser: Yumoto, Keita, Hattori, Takashi, Hasegawa, Hideomi, Matsushita, Akihito, Saitou, Fumie, Mihara, Wahei
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:An 81-year-old Japanese man who had distal aortic arch dilatation at age 77 had thoracic endovascular aortic surgery. The patient developed a fever and was taken to the hospital. Reduced diffusion in the descending aortic wall along the stent graft was discovered using whole-body diffusion-weighted imaging with background body signal suppression, and stent-graft infection was identified. The 16S ribosomal RNA gene analysis and blood culture results identified Campylobacter insulaenigrae as the etiological bacterial species. The patient was released from the hospital after 6 weeks of antibiotic treatment since the swelling and inflammatory response had decreased.
ISSN:1881-641X
1881-6428
DOI:10.3400/avd.cr.23-00006